Don't Wait for Fall, Start Your Project Today! | Enter SPARK10 At Checkout To Get 10% Off Your Order | FREE Shipping On Orders $100+
The FireFlex 316L Flexible Stainless Steel Chimney Liner Tee Kit provides a durable, corrosion-resistant venting system for relining existing masonry chimneys. Its flexible construction helps installers navigate bends, offsets, and irregular flue passages that can make rigid liner installation difficult.
Each complete chimney liner tee kit includes a flexible 316L stainless steel liner, top plate, square-top chimney cap, and a tee with an EZ Connect clamp and bottom cap. The system is suitable for approved wood, pellet, oil, and gas appliance applications and is backed by a transferable lifetime warranty.
A flexible chimney liner is a continuous stainless steel venting system installed inside an existing chimney. It provides a defined pathway for combustion gases to travel from the appliance connection to the chimney termination.
Flexible liners are commonly selected for masonry chimneys with bends, offsets, or irregular interior dimensions. Their construction allows them to follow chimney configurations that may be difficult to navigate with rigid liner sections.
316L stainless steel provides excellent resistance to corrosion in chimney environments where moisture, acidic condensates, and combustion byproducts may be present. This makes it a versatile material for approved wood, pellet, oil, and gas venting applications.
The material combines corrosion resistance with the flexibility required for chimney relining projects. Proper appliance compatibility, liner sizing, insulation, and installation must always follow the appliance manufacturer’s requirements and applicable codes.
| Product type | Flexible stainless steel chimney liner tee kit |
|---|---|
| Liner material | 316L stainless steel |
| Liner construction | Flexible |
| Primary application | Existing masonry chimney relining |
| Compatible fuel categories | Wood, pellet, oil, and gas |
| Appliance connection | Tee with EZ Connect clamp and bottom cap |
| Chimney-top components | Top plate and square-top chimney cap |
| Warranty | Transferable lifetime warranty, subject to warranty terms |
A chimney liner tee creates the horizontal connection between the vertical liner and the heating appliance or connector pipe. It is commonly used when a stove, insert, furnace, boiler, or other approved appliance connects through the side of a masonry chimney.
The bottom cap closes the lower opening of the tee. The EZ Connect clamp helps secure the tee connection to the flexible chimney liner.
The FireFlex 316L Chimney Liner Tee Kit is designed for approved chimney relining applications involving compatible appliances and fuel types.
Always confirm that the selected liner material, diameter, insulation system, and connection components meet the appliance manufacturer’s venting requirements.
A stainless steel chimney liner creates a continuous venting pathway inside an existing masonry chimney. Relining may be required when the original flue liner is damaged, deteriorated, improperly sized, or incompatible with a new heating appliance.
The correct liner can help contain combustion gases and support proper appliance venting. Liner selection and installation should be based on the connected appliance, chimney condition, fuel type, required diameter, and applicable building codes.
| Flexible Chimney Liner | Rigid Chimney Liner |
|---|---|
| Can navigate many chimney bends and offsets | Best suited to straight or consistently aligned flues |
| Installed as a continuous liner section | Installed using connected rigid sections |
| Commonly used for existing chimney relining | Often selected where a straight installation path is available |
| Can simplify installation in irregular masonry chimneys | May require additional access or alignment through offsets |
| 316L Stainless Steel | 304 Stainless Steel |
|---|---|
| Excellent resistance to corrosion | Good general corrosion resistance |
| Commonly selected for multi-fuel applications | Commonly used in approved solid-fuel applications |
| Greater resistance in environments involving acidic condensates | Suitable for applications approved by the liner and appliance manufacturer |
| Compatible with approved wood, pellet, oil, and gas systems | Compatibility depends on the specific product and appliance requirements |
The liner diameter must match the venting requirements of the connected appliance. An improperly sized liner can affect appliance draft and venting performance.
Before ordering, confirm:
Do not reduce or increase the liner diameter unless permitted by the appliance manufacturer and applicable code requirements.
Some installations require chimney liner insulation to meet listing, clearance, or performance requirements. Insulation selection depends on the chimney condition, appliance, fuel type, available flue space, and installation method.
Confirm whether insulation is required before ordering the liner kit. Fireside Chimney Supply also offers pre-insulated chimney liner systems for projects where factory-installed insulation may simplify installation.
Inspect and measure the chimney before installing the flexible liner. Confirm that the liner can pass through the full chimney length, including all bends, offsets, and narrow areas.
The liner is typically lowered or pulled through the masonry chimney and connected to the tee at the appliance-entry point. The top plate supports and seals the liner at the chimney top, while the square-top chimney cap helps protect the liner opening from precipitation, debris, and wildlife.
Installation must follow the FireFlex instructions, appliance manufacturer’s requirements, applicable listing requirements, and local building codes. Professional installation is recommended when the installer is unfamiliar with chimney relining, venting systems, or rooftop work.
The chimney liner must be correctly sized, connected, supported, and terminated for the specific appliance. The chimney should also be inspected and cleaned before installation so hidden obstructions, damaged masonry, creosote deposits, or clearance concerns can be addressed.
A chimney liner alone cannot correct every drafting, appliance, or chimney-condition problem. Proper performance depends on the complete venting system, including the appliance, connector, liner diameter, chimney height, combustion air, and installation conditions.
FireFlex stainless steel chimney liner tee kits are backed by a transferable lifetime warranty, subject to the current warranty requirements, exclusions, inspection requirements, and installation conditions.
Review the complete warranty before installation and maintain the chimney system according to the appliance and liner manufacturer’s requirements.
A chimney liner tee kit includes a flexible vertical chimney liner and the components needed to create a horizontal appliance connection through the side of a masonry chimney.
The kit includes the flexible 316L stainless steel chimney liner, top plate, square-top chimney cap, tee with EZ Connect clamp, and tee bottom cap.
316L stainless steel provides excellent resistance to corrosion and is suitable for approved multi-fuel chimney applications where moisture and acidic condensates may be present.
The flexible construction is designed to navigate many bends and offsets found inside existing masonry chimneys. Measure and inspect the complete installation path before ordering.
Yes, when the liner size, insulation, and installation comply with the wood stove manufacturer’s venting requirements and all applicable codes.
The supplied product information identifies pellet appliances as a compatible application. Verify liner sizing, venting configuration, and installation requirements with the pellet appliance manufacturer.
Yes, for approved oil appliance applications. Confirm the required liner diameter, connector arrangement, and installation requirements before ordering.
The liner may be used with approved gas appliance applications when the material, diameter, and venting configuration meet the appliance manufacturer’s requirements.
The bottom cap closes the lower opening of the tee after the horizontal appliance connection is installed.
The top plate supports the liner at the chimney top and helps close the opening around the liner termination.
The chimney cap helps protect the liner termination from rain, snow, debris, birds, and other wildlife while allowing combustion gases to exit.
Insulation requirements depend on the chimney condition, appliance, fuel type, listing, clearances, and applicable codes. Confirm the requirements before ordering or installing the liner.
Follow the connected appliance manufacturer’s specified vent diameter. Also confirm the available chimney space and any insulation requirements before selecting the liner size.
Chimney relining requires accurate sizing, safe rooftop access, proper appliance connections, and compliance with venting and building-code requirements. Professional installation is recommended when the installer lacks chimney-system experience.
Yes. The liner is backed by a transferable lifetime warranty, subject to the current warranty terms and installation requirements.
Specifications:
Please use the following formula to get the approximate weight of this flexible chimney flue liner. .116 X Diameter X Length = Weight
We strongly recommend using a polypropylene chimney brush versus any metal chimney brush. Polypropylene is non-abrasive and does not scrape the interior of the chimney liner. Metal brushes have an adverse effect on the liner.
Download The Installation Document Click Here